{"id":102546,"date":"2026-06-26T14:54:53","date_gmt":"2026-06-26T12:54:53","guid":{"rendered":"https:\/\/port.lukasiewicz.gov.pl\/photonic-biosensor-from-lukasiewicz-port-moves-to-the-next-stage-of-development-with-funding-from-the-polish-ministry-of-science-and-higher-education\/"},"modified":"2026-06-26T16:08:04","modified_gmt":"2026-06-26T14:08:04","slug":"photonic-biosensor-from-lukasiewicz-port-moves-to-the-next-stage-of-development-with-funding-from-the-polish-ministry-of-science-and-higher-education","status":"publish","type":"post","link":"https:\/\/port.lukasiewicz.gov.pl\/en\/photonic-biosensor-from-lukasiewicz-port-moves-to-the-next-stage-of-development-with-funding-from-the-polish-ministry-of-science-and-higher-education\/","title":{"rendered":"Photonic Biosensor from \u0141ukasiewicz \u2013 PORT Moves to the Next Stage of Development with Funding from the Polish Ministry of Science and Higher Education"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"102546\" class=\"elementor elementor-102546 elementor-102533\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5637f161 e-flex e-con-boxed e-con e-parent\" data-id=\"5637f161\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-562c6b37 cut-off-wrapper-90 elementor-widget elementor-widget-text-editor\" data-id=\"562c6b37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b><span data-contrast=\"auto\">Nearly PLN 2 million in funding awarded by the Polish Ministry of Science and Higher Education will support further work on a photonic biosensor that may in the future enable fast and highly sensitive medical diagnostics directly at the point of patient care.<\/span><\/b><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f0f1b35 e-flex e-con-boxed e-con e-parent\" data-id=\"f0f1b35\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4089bbf elementor-widget elementor-widget-text-editor\" data-id=\"4089bbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">The SENSOPTIC project \u2013 \u201cIntegrated Optical Sensor for Early Disease Diagnostics Based on Photonic Structures\u201d \u2013 builds on research initiated at \u0141ukasiewicz \u2013 PORT under the institute\u2019s internal PORT TECH CALL program in 2025. Researchers will continue developing a photonic biosensor: a miniature device that uses light to detect the presence of specific biological substances in a sample. This type of technology could help bring diagnostics closer to patients, accelerate testing, and reduce the need to transport samples to specialized laboratories. <\/span><\/p><p><span data-contrast=\"auto\">\u201cThis project continues work in which we have been building our expertise step by step: from designing photonic structures and fabricating them, to carrying out initial detection tests. Funding from the Ministry of Science and Higher Education allows us to move from verifying the technological foundations to developing a prototype with an increasingly well-defined medical application,\u201d says Dr. hab. Joanna Cybi\u0144ska, Deputy Director for R&amp;D at \u0141ukasiewicz \u2013 PORT. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d9a239 e-flex e-con-boxed e-con e-parent\" data-id=\"4d9a239\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e81f12 elementor-widget elementor-widget-heading\" data-id=\"1e81f12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">From Simple Substances to Biomarkers <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7a2b04b e-flex e-con-boxed e-con e-parent\" data-id=\"7a2b04b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eddbfbb elementor-widget elementor-widget-text-editor\" data-id=\"eddbfbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">In the first stage of the work, researchers focused on designing and fabricating photonic structures capable of detecting simple chemical analytes, such as water or isopropyl alcohol. The key goal was to determine whether changes in the optical properties of the surrounding environment could be used for precise, real-time detection of substances. <\/span><\/p><p><span data-contrast=\"auto\">The results confirmed that photonic phenomena can provide a strong foundation for advanced sensing technologies. The next step was to move from detecting simple chemical compounds toward biological applications. A multidisciplinary team began developing methods for activating and functionalizing the surfaces of photonic layers \u2013 in other words, preparing the sensor surface so that it can selectively bind specific biological molecules. <\/span><\/p><p><span data-contrast=\"auto\">\u201cWhat matters most in this technology is the ability to combine a sensitive optical system with a surface that can be biologically \u2018programmed\u2019 for a specific diagnostic target. This means we are not thinking about a single sensor for a single application, but about a platform that could in the future be adapted to detect a wide range of biomarkers,\u201d explains Dr. hab. Joanna Cybi\u0144ska. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3e15b9e e-flex e-con-boxed e-con e-parent\" data-id=\"3e15b9e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e632df elementor-widget elementor-widget-heading\" data-id=\"5e632df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How Does a Photonic Biosensor Work? <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6095fdc e-flex e-con-boxed e-con e-parent\" data-id=\"6095fdc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-93c6875 elementor-widget elementor-widget-text-editor\" data-id=\"93c6875\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">The biosensor being developed at \u0141ukasiewicz \u2013 PORT is based on advanced photonic structures, such as Mach-Zehnder interferometers and photonic crystals, integrated with thin-film SiOx waveguides. In practical terms, this creates a miniature system in which light carries information about what is happening on the sensor surface. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">When the target biomarker binds to a properly prepared surface, the optical properties of the system change. The sensor can detect this change without the need for additional chemical labels. This is why the technology is described as label-free.  <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">Under the newly funded project, the team will focus on developing a device capable of rapidly and selectively detecting selected biomarkers. In the first phase, the biosensor will be adapted to measure steroid hormones, such as estrogen and progesterone. At the same time, the technology is being designed from the outset as a platform solution that could later be adapted to detect a broader spectrum of bioanalytes, including proteins, peptides, exosomes, bacteria, and viruses.   <\/span><span data-ccp-props=\"{}\"> <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a3fdd9f e-flex e-con-boxed e-con e-parent\" data-id=\"a3fdd9f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c96613 elementor-widget elementor-widget-image\" data-id=\"2c96613\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"600\" src=\"https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit.jpg\" class=\"attachment-full size-full wp-image-102543\" alt=\"\" srcset=\"https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit.jpg 900w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit-300x200.jpg 300w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit-768x512.jpg 768w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit-24x16.jpg 24w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit-36x24.jpg 36w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/L34A4072-Edit-48x32.jpg 48w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f9f349 e-flex e-con-boxed e-con e-parent\" data-id=\"3f9f349\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d3d5aa3 elementor-widget elementor-widget-heading\" data-id=\"d3d5aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Diagnostics Closer to the Patient <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-973ff32 e-flex e-con-boxed e-con e-parent\" data-id=\"973ff32\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2ff88f3 elementor-widget elementor-widget-text-editor\" data-id=\"2ff88f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">One of the main assumptions behind the project is that the biosensor could be used in a point-of-care testing model, directly where patient care is provided. Ultimately, test results could be available within several minutes. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">In the future, such a solution could shorten diagnostic timelines, improve access to testing outside large urban centers, and reduce pressure on the healthcare system. This is particularly important in medical areas where rapid biomarker identification can support clinical decision-making and enable more personalized therapies. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fc55915 e-flex e-con-boxed e-con e-parent\" data-id=\"fc55915\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4157f04 elementor-widget elementor-widget-heading\" data-id=\"4157f04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">One Platform, Many Possibilities<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7188a28 e-flex e-con-boxed e-con e-parent\" data-id=\"7188a28\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8426397 elementor-widget elementor-widget-text-editor\" data-id=\"8426397\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">The technology developed at \u0141ukasiewicz \u2013 PORT aligns with a global trend toward biosensor-based diagnostics. Optical and photonic solutions are advancing particularly rapidly because they offer high measurement sensitivity, enable real-time analysis, and eliminate the need for chemical labels. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">A key advantage of the approach developed at the institute is its potential versatility. Unlike many single-use biosensors, whose applications are limited from the start to one type of measurement, this solution is designed to allow modification of the bioreceptor layer without fundamentally changing the optical system itself. This opens the way to creating entire families of diagnostic devices based on a single technology platform.  <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">The expected outcome of the project is a demonstrator of a photonic biosensor transducer that will confirm the feasibility of the technology and enable further application-oriented work toward implementation.<\/span><span data-ccp-props=\"{}\"> <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8f9350 e-flex e-con-boxed e-con e-parent\" data-id=\"c8f9350\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-103b2c6 elementor-widget elementor-widget-heading\" data-id=\"103b2c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Photonics, Biotechnology, and Materials Engineering <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-329fba2 e-flex e-con-boxed e-con e-parent\" data-id=\"329fba2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95eae75 elementor-widget elementor-widget-text-editor\" data-id=\"95eae75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span data-contrast=\"auto\">\u0141ukasiewicz \u2013 PORT brings together diverse technological approaches: from the design and fabrication of photonic systems, through their biological functionalization, to the development of microfluidic sample analysis systems and the miniaturization of diagnostic platforms. The institute\u2019s advanced laboratory infrastructure is also an important asset, enabling research and biological validation of the developed solutions under controlled conditions. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">\u201cThe biosensor we are developing is part of a broader ecosystem of expertise that we are building at our institute. We combine photonics, bioengineering, and materials technologies to create solutions that can respond to the real needs of modern diagnostics,\u201d adds Dr. hab. Joanna Cybi\u0144ska.  <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">The SENSOPTIC project is expected to provide new research methods in photonics and bioengineering and, in the longer term, lay the groundwork for the commercialization of compact biosensors. The material and technological platform developed within the project could eventually be applied across a broad spectrum of molecular diagnostics. <\/span><span data-ccp-props=\"{}\"> <\/span><\/p><p><span data-contrast=\"auto\">The project is financed from the state budget funds awarded by the Minister of Science and Higher Education under the \u201cScience for Society Development\u201d program.<\/span><span data-ccp-props=\"{}\"> <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fbd72f2 e-flex e-con-boxed e-con e-parent\" data-id=\"fbd72f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-21e0bc7 elementor-widget elementor-widget-image\" data-id=\"21e0bc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img alt=\"\" decoding=\"async\" width=\"900\" height=\"600\" src=\"https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit.jpg\" class=\"attachment-full size-full wp-image-102544\" alt=\"\" srcset=\"https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit.jpg 900w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit-300x200.jpg 300w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit-768x512.jpg 768w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit-24x16.jpg 24w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit-36x24.jpg 36w, https:\/\/lukasiewicz.gov.pl\/wp-content\/uploads\/sites\/35\/2026\/06\/DSCF0630-Edit-48x32.jpg 48w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>With nearly PLN 2 million in new funding, \u0141ukasiewicz \u2013 PORT will advance work on a photonic biosensor designed to support fast, sensitive diagnostics closer to the patient.<\/p>\n","protected":false},"author":250,"featured_media":102545,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[642],"class_list":["post-102546","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bez-kategorii","tag-badania"],"acf":[],"publishpress_future_action":{"enabled":false,"date":"2026-07-03 20:40:39","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"category","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/posts\/102546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/users\/250"}],"replies":[{"embeddable":true,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/comments?post=102546"}],"version-history":[{"count":5,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/posts\/102546\/revisions"}],"predecessor-version":[{"id":102553,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/posts\/102546\/revisions\/102553"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/media\/102545"}],"wp:attachment":[{"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/media?parent=102546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/categories?post=102546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/port.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/tags?post=102546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}